Unreinforced masonry dressed stone#
Structural fragility parameters#
Building class |
Intensity measure |
Median slight damage |
Median moderate damage |
Median extensive damage |
Median complete damage |
Logarithmic standard deviation |
---|---|---|---|---|---|---|
MUR+STDRE/LWAL+DNO/H1 |
SA(0.3s) |
0.4447941308808734 |
0.8410324112579068 |
1.1822894203662746 |
1.4797605085408643 |
0.5868989640419033 |
MUR+STDRE/LWAL+DNO/H2 |
SA(0.3s) |
0.4665843879925317 |
0.9329988619225251 |
1.351395712035677 |
1.725084216181507 |
0.6460760694544043 |
MUR+STDRE/LWAL+DNO/H3 |
SA(0.6s) |
0.23764367514530227 |
0.4493585069806033 |
0.6491860407974206 |
0.8326994356476881 |
0.5809971455020844 |
MUR+STDRE/LWAL+DNO/H4 |
SA(0.6s) |
0.27352159483058225 |
0.48977379905836194 |
0.6956412704432853 |
0.8854618520283104 |
0.5327895980641426 |
MUR+STDRE/LWAL+DNO/H5 |
SA(0.6s) |
0.2995701663154619 |
0.5030782937193874 |
0.6978145239020568 |
0.8776964955297468 |
0.50998889629814 |
Structural fragility curves#